Weiss
Model: WK11-1000/40
For sale is a professional Weiss Umwelttechnik WT-WK 1000/40 climate test chamber with fully automatic cold-regenerating adsorption dryer.
The installed fixtures in the test chamber can be removed if required. Currently, due to these fixtures, the control cabinet is limited to a temperature range of −40°C to +60°C. Once the fixtures are removed, the manufacturer can expand the temperature range back to the standard values of −40°C to +180°C, as the fixtures are not suitable for these higher temperatures.
This equipment is ideal for precise temperature and humidity testing on components, assemblies, and devices. It is perfectly suited for applications in industry, development, quality assurance, and research.
Gusdpfex Hxkzox Ag Usa
Weiss Climate Test Chamber – Water Cooled
Data for Temperature Tests:
- Temperature range: −40°C to +60°C
- Temporal temperature fluctuation (at center of usable space): ± 0.1 to ± 0.5 K
- Spatial temperature deviation: ± 0.5 to ± 2.0 K
- Temperature change rate:
- Heating: 4 K/min
- Cooling: 3 K/min
Data for Climate Tests:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % r. H.
- Temporal temperature fluctuation (at center): ± 0.1 to ± 0.3 K
- Spatial temperature deviation: ± 0.5 to ± 1 K
- Temporal humidity fluctuation (at center): ± 1 to ± 3 % r. H.
- Thermal compensation:
- In the range of +25°C to +95°C
- At a relative humidity of up to 90%, 500 W
Humidification System Data:
- Reservoir volume: 20 l
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 μS/cm³
- Water consumption at constant +40°C, 92% r. H.: 21/24 h
- Temperature gradient:
- (according to IEC 60068-3-5): 1 to 2 K
Test Chamber Dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External Dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test Chamber Volume: approx. 990 liters
Nominal Voltage: 3/N / PE AC 400 V +10% 50 Hz
Nominal Power: 11.5 kW, Nominal Current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to modifications and errors!)
Further questions can be answered via telephone.
该广告为自动翻译,可能存在翻译错误。
Model: WK11-1000/40
For sale is a professional Weiss Umwelttechnik WT-WK 1000/40 climate test chamber with fully automatic cold-regenerating adsorption dryer.
The installed fixtures in the test chamber can be removed if required. Currently, due to these fixtures, the control cabinet is limited to a temperature range of −40°C to +60°C. Once the fixtures are removed, the manufacturer can expand the temperature range back to the standard values of −40°C to +180°C, as the fixtures are not suitable for these higher temperatures.
This equipment is ideal for precise temperature and humidity testing on components, assemblies, and devices. It is perfectly suited for applications in industry, development, quality assurance, and research.
Gusdpfex Hxkzox Ag Usa
Weiss Climate Test Chamber – Water Cooled
Data for Temperature Tests:
- Temperature range: −40°C to +60°C
- Temporal temperature fluctuation (at center of usable space): ± 0.1 to ± 0.5 K
- Spatial temperature deviation: ± 0.5 to ± 2.0 K
- Temperature change rate:
- Heating: 4 K/min
- Cooling: 3 K/min
Data for Climate Tests:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % r. H.
- Temporal temperature fluctuation (at center): ± 0.1 to ± 0.3 K
- Spatial temperature deviation: ± 0.5 to ± 1 K
- Temporal humidity fluctuation (at center): ± 1 to ± 3 % r. H.
- Thermal compensation:
- In the range of +25°C to +95°C
- At a relative humidity of up to 90%, 500 W
Humidification System Data:
- Reservoir volume: 20 l
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 μS/cm³
- Water consumption at constant +40°C, 92% r. H.: 21/24 h
- Temperature gradient:
- (according to IEC 60068-3-5): 1 to 2 K
Test Chamber Dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External Dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test Chamber Volume: approx. 990 liters
Nominal Voltage: 3/N / PE AC 400 V +10% 50 Hz
Nominal Power: 11.5 kW, Nominal Current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to modifications and errors!)
Further questions can be answered via telephone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
这些广告您可能也感兴趣。
小广告
Werlte
9,369 km
立式加工中心
HedeliusT8-3200 Magnum
HedeliusT8-3200 Magnum
小广告
Borken
9,474 km
带湿度的气候试验箱
Weiss -72°C bis +180°CWK3-340/70
Weiss -72°C bis +180°CWK3-340/70
小广告
Niederlangen
9,390 km
立式钻床
IXIONBT 15 GL E
IXIONBT 15 GL E
小广告
Janville
10,000 km
高压灭菌器
De lamaDLST/L Class 100
De lamaDLST/L Class 100
小广告
Werlte
9,369 km
立式加工中心
HedeliusBC100 -3500
HedeliusBC100 -3500
小广告
Borken
9,474 km
温度室 2000 升
CTST-40/2000 -40°C bis +180°C
CTST-40/2000 -40°C bis +180°C
小广告
Goudriaan
9,584 km
碎木机
Boxer AgriMaster 175
Boxer AgriMaster 175
小广告
Wesel
9,505 km
振动光饰机
ERBAYE 60 Separierstrecke
ERBAYE 60 Separierstrecke
小广告
Wesel
9,505 km
振动光饰机
ERBAEVT 80 Langtrogvibrator
ERBAEVT 80 Langtrogvibrator
小广告
Werlte
9,369 km
立式加工中心
HedeliusC80-2300
HedeliusC80-2300
您的广告已成功删除
发生错误