带湿度的气候试验箱Weiss -72°C bis +180°C
WK3-340/70
带湿度的气候试验箱
Weiss -72°C bis +180°C
WK3-340/70
状况
二手
位置
Borken 

显示图片
显示地图
机器数据
价格和位置
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

拨打
优惠详情
- 广告编号:
- A18791221
- 参考编号:
- 24566
- 更新:
- 最近更新时间为 02.07.2025
描述
Weiss
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Cgodpfxsv Sr Hzs Ahvep
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
该广告为自动翻译,可能存在翻译错误。
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Cgodpfxsv Sr Hzs Ahvep
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
该广告为自动翻译,可能存在翻译错误。
这些广告您可能也感兴趣。
小广告
Karlsbad
9,554 km
工具夹/工具架
EROWAER-010561, ER-008617, ER-035297
EROWAER-010561, ER-008617, ER-035297
小广告
Saarbrücken
9,632 km
光学测量机 多传感器
MahrMS2VT Refurbished mit Garantie
MahrMS2VT Refurbished mit Garantie
小广告
Petrovče
9,262 km
木材粉碎机
RobustHD 1500/45kW with Z conveyor
RobustHD 1500/45kW with Z conveyor
小广告
Sittard
9,584 km
多功能车辆 (UTV)
John DeereGator HPX 815E | 2019 | 490 h
John DeereGator HPX 815E | 2019 | 490 h
小广告
Kassel
9,352 km
部分
FendtFrontlader CARGO 5X/85 DW
FendtFrontlader CARGO 5X/85 DW
小广告
Contamine-sur-Arve
9,857 km
卧式加工中心
QUASERHX404BP/15C
QUASERHX404BP/15C
小广告
Villingen-Schwenningen
9,598 km
高性能冲孔机
BRUDERERBSTA 50 USL
BRUDERERBSTA 50 USL
小广告
Grafenau
9,245 km
自动冲孔机
BRUDERERBSTA 300
BRUDERERBSTA 300
小广告
Miskolc
8,789 km
数控车床
SpinnerTS66L-SMC
SpinnerTS66L-SMC
小广告
Borken
9,474 km
带湿度的气候箱 34 升
WeissWKL 34/60 -60°C bis 150°C
WeissWKL 34/60 -60°C bis 150°C
您的广告已成功删除
发生错误