化学分析仪Bayer
Advia 1650
化学分析仪
Bayer
Advia 1650
EXW 固定价格 不包含增值稅
€4,000
狀況
二手
位置
Budapest 

顯示圖片
显示地图
机器数据
价格和位置
EXW 固定价格 不包含增值稅
€4,000
- 位置:
- Budapest, Hungary

撥打
优惠详情
- 產品ID:
- A14339923
- 最後更新:
- 於 26.11.2024
描述
The ADVIA 1650 has minimal requirements for sample volume (as low as 2 µL/test), reagent consumption (as low as 80 µL/test) and water consumption (25 L/hour) – thus maximizing management efficiency. A rapid, 3-second cycle and system throughput of up to 1650 tests/hour provide powerful high-speed performance, ensure workflow efficiency through peak workloads. Optional universal rack handler facilitates continuous sample feeding for further productivity gains.
Psdpfeqzx Ixex Aalorc
Measurement point: 98 detection points/ 6 seconds in 10 minute reaction
Photometer: Concavity diffraction grating, rear spectroscopy system
Measurement wavelength: 14 fixed wavelengths (340, 410 ,451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, 884 nm), 1 or 2 wavelenth calculation
Light source: 12V, 50W halogen lamp, cooled by forced water circulation
Assay method: Colorimetric assays – Endpoint assays (EPA), Reaction rate assays (RRA), 2-point rate assays (2PA), 3-item simultaneous measurement (parameter independent), Prozone checking (antigen excess check) Substrate depletion check with point forwarding option, Sample blank correction
Reassay mechanism: Automatic or manual (selectable)
Automatic correction: Blood serum blank, cell blank, measurement point change, sample volume change in reassay
Measurement method: Open discrete – Single line, simultaneous, multi item measurement
Throughput rate: Maximum 1650 tests/hour
Throughput rate biochemistry : Maximum 1200 tests/hour
Throughput rate electrolyte: Maximum 450 tests/hour
Sample throughput rate: Maximum 1200 samples/hour
Simultaneous measurement item: Maximum 103 items, normally 50 (main system) + 3 (ISE)
Measurement sample: Blood serum, plasma and urine (method dependent)
Containers: 5 mL, 7mL, 10 mL collection tubes (dead volume for collection tubes is 200 µL)
Cups: 1.8 mL JEOL sample cups (STT only), Hitachi 2 mL sample cups and Immuno 2 mL sample cups in 7 mL (16 x 75 mm) collection tubes (URH) or STT sample adapter (dead volume for sample cups is 50 µL)
No software with the unit. Please check out our other listings as well.
Psdpfeqzx Ixex Aalorc
Measurement point: 98 detection points/ 6 seconds in 10 minute reaction
Photometer: Concavity diffraction grating, rear spectroscopy system
Measurement wavelength: 14 fixed wavelengths (340, 410 ,451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, 884 nm), 1 or 2 wavelenth calculation
Light source: 12V, 50W halogen lamp, cooled by forced water circulation
Assay method: Colorimetric assays – Endpoint assays (EPA), Reaction rate assays (RRA), 2-point rate assays (2PA), 3-item simultaneous measurement (parameter independent), Prozone checking (antigen excess check) Substrate depletion check with point forwarding option, Sample blank correction
Reassay mechanism: Automatic or manual (selectable)
Automatic correction: Blood serum blank, cell blank, measurement point change, sample volume change in reassay
Measurement method: Open discrete – Single line, simultaneous, multi item measurement
Throughput rate: Maximum 1650 tests/hour
Throughput rate biochemistry : Maximum 1200 tests/hour
Throughput rate electrolyte: Maximum 450 tests/hour
Sample throughput rate: Maximum 1200 samples/hour
Simultaneous measurement item: Maximum 103 items, normally 50 (main system) + 3 (ISE)
Measurement sample: Blood serum, plasma and urine (method dependent)
Containers: 5 mL, 7mL, 10 mL collection tubes (dead volume for collection tubes is 200 µL)
Cups: 1.8 mL JEOL sample cups (STT only), Hitachi 2 mL sample cups and Immuno 2 mL sample cups in 7 mL (16 x 75 mm) collection tubes (URH) or STT sample adapter (dead volume for sample cups is 50 µL)
No software with the unit. Please check out our other listings as well.