阴离子交换分析型高效液相色谱柱Thermo Fisher Scientific
Dionex IonPac AS12A
阴离子交换分析型高效液相色谱柱
Thermo Fisher Scientific
Dionex IonPac AS12A
EXW 固定价格 不含增值税
€650
出厂年份
2022
状况
全新
(完全功能)
位置
Töltéstava 

基本数据
价格和位置
EXW 固定价格 不含增值税
€650
- 位置:
- 0184/3. Hrsz, 9086 Töltéstava, Hungary

拨打
优惠详情
- 广告编号:
- A23090061
- 更新:
- 最近更新时间为 20.10.2026
描述
Physical & Physical-Chemical Properties
• Product Number: 046034
• Column Dimensions: 4 mm ID × 200 mm Length (Standard Bore, Analytical Format)
Kdsdpfx Aj Aay Rqjcbsu
• Stationary Phase Packing Material: Ethylvinylbenzene / Divinylbenzene (EVB/DVB) macroporous polymer.
• Crosslinking: 55%
• Particle Size: 9 µm
• Pore Size: 2000 Å
• Anion Exchange Capacity: 52 µeq per column
• Functional Group: Alkyl quaternary ammonium
• Maximum Pressure Limit: 4,000 psi (275 bar)
• Solvent Compatibility: pH 0 to 14; compatible with 0 to 100% HPLC solvents
• Hardware Interface: Device Monitoring Enabled and Viper Fitting Ready
Recommended Standard QAR Operating Conditions
• Eluent Composition: 2.7 mM Na₂CO₃ / 0.3 mM NaHCO₃ (Sodium Carbonate / Sodium Bicarbonate)
• Flow Rate: 1.50 mL/min
• Operating Temperature: Ambient temperature
• Detection Method: Suppressed Conductivity
• Recommended Suppressor: Dionex Anion Self-Regenerating Suppressor (Dionex ASRS 300 4mm or equivalent) operated in AutoSuppression Recycle Mode.
• Applied Suppressor Current: 22 mA
• Injection Volume: 10 µL
• Storage Solution: 100 mM NaOH (Sodium Hydroxide).
Good working condition. Please check out our other listings as well.
• Product Number: 046034
• Column Dimensions: 4 mm ID × 200 mm Length (Standard Bore, Analytical Format)
Kdsdpfx Aj Aay Rqjcbsu
• Stationary Phase Packing Material: Ethylvinylbenzene / Divinylbenzene (EVB/DVB) macroporous polymer.
• Crosslinking: 55%
• Particle Size: 9 µm
• Pore Size: 2000 Å
• Anion Exchange Capacity: 52 µeq per column
• Functional Group: Alkyl quaternary ammonium
• Maximum Pressure Limit: 4,000 psi (275 bar)
• Solvent Compatibility: pH 0 to 14; compatible with 0 to 100% HPLC solvents
• Hardware Interface: Device Monitoring Enabled and Viper Fitting Ready
Recommended Standard QAR Operating Conditions
• Eluent Composition: 2.7 mM Na₂CO₃ / 0.3 mM NaHCO₃ (Sodium Carbonate / Sodium Bicarbonate)
• Flow Rate: 1.50 mL/min
• Operating Temperature: Ambient temperature
• Detection Method: Suppressed Conductivity
• Recommended Suppressor: Dionex Anion Self-Regenerating Suppressor (Dionex ASRS 300 4mm or equivalent) operated in AutoSuppression Recycle Mode.
• Applied Suppressor Current: 22 mA
• Injection Volume: 10 µL
• Storage Solution: 100 mM NaOH (Sodium Hydroxide).