Glasses
Type: ACM 18
Machine control: SIEMENS PLC S7-1200
Safety controller: SICK Flexi Soft
1 media circuit (hydrocarbon)
Feed pump: adjustable gear pump (24 V)
Vacuum pump: diaphragm pump (230 V / 50 Hz)
1 liftable/pivoting membrane holder with 3 removable cascade rings for filter membranes with a diameter of 47 mm.
System filter: 0.2 µm; length: 5 inches
Lsdpjwaypfefx Af Asah
Return filter: 5.0 µm; Length: 5 inches
System pressure: maximum 6 bar
Maximum flow rate: 2.0 l/min
Minimum flow rate: 0.250 l/min
Maximum system temperature: 41°C
Tank volume: approx. 12.8 liters
Tank can be filled via a manual 3-way ball valve
Recirculation and reuse of the rinsing medium
Permissible ambient temperature: +15…+25°C
Noise emissions are below 70 dB (A)
Flow-cap top with 1 particle filter (separation efficiency: 99.995%; filter class: H14 HEPA filter according to EN 1822)
Employee protection against splashing analysis fluid thanks to a sliding guard
Collecting tray under the membrane holder
Operation via 12" BASIC touch panel (optional COMFORT panel)
Operation via glass keypad and stylus with the 12" option COMFORT touch panel
32 different test programs, each with 30 rinsing steps
Functions: Spraying, rinsing, ultrasound
Basin 750 x 600 x 500 (W x D x H) mm with a usable volume of approximately 5 l for ultrasound (with hemisphere Ø300)
Hinged safety screen with three movable panels for manual access (protects employees from splashing analysis fluid)
Quick coupling in the basin area for connecting various nozzles. A 2.5 mm diameter nozzle is included.
Insertion opening for components: approx. 1100 x 2200 mm (W x H)
Basket for ultrasonic application for components up to 3 kg
Product support grid for components up to 15 kg
Extraction methods: spraying, rinsing, internal rinsing (optional), ultrasound
Medium: Cold cleaner A III
Analysis membrane Ø 47 mm (up to 3 pieces)
Blank value: < 150 µm (from at least SaS 2 or SaS 3)
Power supply (machine): 230 VAC 10%, 50/60 Hz
Rated power: 500 W
Rated current: 2 A
Back-up fuse: 16 A (max.)
Supply cable: at least 3 x 1.5 mm²
Control voltage: 24 VDC3)
External dimensions:
H x W x D 1922 x 800 x 893 mm
Weight: 324 kg
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
Type: ACM 18
Machine control: SIEMENS PLC S7-1200
Safety controller: SICK Flexi Soft
1 media circuit (hydrocarbon)
Feed pump: adjustable gear pump (24 V)
Vacuum pump: diaphragm pump (230 V / 50 Hz)
1 liftable/pivoting membrane holder with 3 removable cascade rings for filter membranes with a diameter of 47 mm.
System filter: 0.2 µm; length: 5 inches
Lsdpjwaypfefx Af Asah
Return filter: 5.0 µm; Length: 5 inches
System pressure: maximum 6 bar
Maximum flow rate: 2.0 l/min
Minimum flow rate: 0.250 l/min
Maximum system temperature: 41°C
Tank volume: approx. 12.8 liters
Tank can be filled via a manual 3-way ball valve
Recirculation and reuse of the rinsing medium
Permissible ambient temperature: +15…+25°C
Noise emissions are below 70 dB (A)
Flow-cap top with 1 particle filter (separation efficiency: 99.995%; filter class: H14 HEPA filter according to EN 1822)
Employee protection against splashing analysis fluid thanks to a sliding guard
Collecting tray under the membrane holder
Operation via 12" BASIC touch panel (optional COMFORT panel)
Operation via glass keypad and stylus with the 12" option COMFORT touch panel
32 different test programs, each with 30 rinsing steps
Functions: Spraying, rinsing, ultrasound
Basin 750 x 600 x 500 (W x D x H) mm with a usable volume of approximately 5 l for ultrasound (with hemisphere Ø300)
Hinged safety screen with three movable panels for manual access (protects employees from splashing analysis fluid)
Quick coupling in the basin area for connecting various nozzles. A 2.5 mm diameter nozzle is included.
Insertion opening for components: approx. 1100 x 2200 mm (W x H)
Basket for ultrasonic application for components up to 3 kg
Product support grid for components up to 15 kg
Extraction methods: spraying, rinsing, internal rinsing (optional), ultrasound
Medium: Cold cleaner A III
Analysis membrane Ø 47 mm (up to 3 pieces)
Blank value: < 150 µm (from at least SaS 2 or SaS 3)
Power supply (machine): 230 VAC 10%, 50/60 Hz
Rated power: 500 W
Rated current: 2 A
Back-up fuse: 16 A (max.)
Supply cable: at least 3 x 1.5 mm²
Control voltage: 24 VDC3)
External dimensions:
H x W x D 1922 x 800 x 893 mm
Weight: 324 kg