热流道控制器Günther
DPT 6
热流道控制器
Günther
DPT 6
製造年份
2019
狀況
二手
位置
Langenfeld (Rheinland) 

顯示圖片
显示地图
价格和位置
- 位置:
- Schneiderstrasse 10, 40764 Langenfeld, Deutschland

撥打
优惠详情
- 產品ID:
- A20576510
- 參考編號:
- 503655
- 最後更新:
- 於 20.11.2025
描述
Hot Runner Controller Günther DPT 6
Stock No.: 503655
Machine / Equipment Type: Hot Runner Controllers
Manufacturer: Günther
Model: DPT 6
Year of Manufacture: 2019
SUPPLY VOLTAGE
Per phase 200–250 VAC, 50 to 60 Hz, typical.
Star connection: 3-phase network with neutral conductor, 200–250 V between L and N.
Delta connection: 3-phase network without neutral conductor, 200–250 V between any two phases.
LOAD CONNECTION
16A per channel (protection: 16A fast-blow fuse, "FF 16A")
Phase load: maximum 32A
Phase L1: Channels 1 - 6, 19 - 24
Phase L2: Channels 7 - 12
Phase L3: Channels 13 - 18
MAXIMUM OUTPUT
DPT6: 7.3 kW (1 x 32A)
LOAD TYPE
Resistive loads only permitted
Kjdpfexx Ti Tox Abhedw
SENSOR CONNECTION
Thermocouple type L (Fe-CuNi) (electronic compensation)
Thermocouple type J (Fe-CuNi) (electronic compensation)
Thermocouple type K (NiCr-Ni) (electronic compensation)
Thermocouple type N (NiCrSi-NiSi) (electronic compensation)
OK OUTPUT
Potential-free relay contact (max. 230V/1A, not fused)
BOOST INPUT
Connection for a potential-free relay contact
POWER CABLE
CEE plug 32 A (configured for star wiring)
HOT RUNNER CONNECTION (HK)
Load connection: 2 x 24-pin HAN-E female sockets
Thermo connection: 2 x 24-pin HAN-E male sockets
FUSES
Load output fuse: FF 16A, 6.3 x 32mm, Schurter SA type
Control fuse: slow-blow 2A, 5 x 20 mm
SERIAL INTERFACE
RS232, TTY, (RS422, RS485)
Interface protocols available for Arburg, Mannesmann, Krauss-Maffei, Engel, and others.
OUTPUT
Continuous via pulse group control
CONTROL RANGE
Adjustable from 0 to 700°C / 0 to 999°F
DECREASE (SETBACK)
Adjustable from 0 to 200°C / 0 to 360°F
INCREASE (BOOST)
Adjustable from 0 to 100°C / 0 to 180°F
SAFETY SHUTDOWN
Adjustable from 0 to 700°C / 0 to 999°F
DATA BACKUP
Power-failure resistant, data retention for at least 10 years
STORAGE TEMPERATURE
0 to 70°C
OPERATING TEMPERATURE
0 to 40°C
HUMIDITY
Storage: 30% - 80%, non-condensing
Operation: 40% - 70%, non-condensing
PROTECTION CLASS
IP 20
DIMENSIONS (W x H x D)
362 mm x 180 mm x (depth missing)
Approx. 16.0 kg
HOUSING COLOUR
Aluminum / blue / grey (RAL 9006 / RAL 5002)
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
Stock No.: 503655
Machine / Equipment Type: Hot Runner Controllers
Manufacturer: Günther
Model: DPT 6
Year of Manufacture: 2019
SUPPLY VOLTAGE
Per phase 200–250 VAC, 50 to 60 Hz, typical.
Star connection: 3-phase network with neutral conductor, 200–250 V between L and N.
Delta connection: 3-phase network without neutral conductor, 200–250 V between any two phases.
LOAD CONNECTION
16A per channel (protection: 16A fast-blow fuse, "FF 16A")
Phase load: maximum 32A
Phase L1: Channels 1 - 6, 19 - 24
Phase L2: Channels 7 - 12
Phase L3: Channels 13 - 18
MAXIMUM OUTPUT
DPT6: 7.3 kW (1 x 32A)
LOAD TYPE
Resistive loads only permitted
Kjdpfexx Ti Tox Abhedw
SENSOR CONNECTION
Thermocouple type L (Fe-CuNi) (electronic compensation)
Thermocouple type J (Fe-CuNi) (electronic compensation)
Thermocouple type K (NiCr-Ni) (electronic compensation)
Thermocouple type N (NiCrSi-NiSi) (electronic compensation)
OK OUTPUT
Potential-free relay contact (max. 230V/1A, not fused)
BOOST INPUT
Connection for a potential-free relay contact
POWER CABLE
CEE plug 32 A (configured for star wiring)
HOT RUNNER CONNECTION (HK)
Load connection: 2 x 24-pin HAN-E female sockets
Thermo connection: 2 x 24-pin HAN-E male sockets
FUSES
Load output fuse: FF 16A, 6.3 x 32mm, Schurter SA type
Control fuse: slow-blow 2A, 5 x 20 mm
SERIAL INTERFACE
RS232, TTY, (RS422, RS485)
Interface protocols available for Arburg, Mannesmann, Krauss-Maffei, Engel, and others.
OUTPUT
Continuous via pulse group control
CONTROL RANGE
Adjustable from 0 to 700°C / 0 to 999°F
DECREASE (SETBACK)
Adjustable from 0 to 200°C / 0 to 360°F
INCREASE (BOOST)
Adjustable from 0 to 100°C / 0 to 180°F
SAFETY SHUTDOWN
Adjustable from 0 to 700°C / 0 to 999°F
DATA BACKUP
Power-failure resistant, data retention for at least 10 years
STORAGE TEMPERATURE
0 to 70°C
OPERATING TEMPERATURE
0 to 40°C
HUMIDITY
Storage: 30% - 80%, non-condensing
Operation: 40% - 70%, non-condensing
PROTECTION CLASS
IP 20
DIMENSIONS (W x H x D)
362 mm x 180 mm x (depth missing)
Approx. 16.0 kg
HOUSING COLOUR
Aluminum / blue / grey (RAL 9006 / RAL 5002)