荧光光谱仪Agilent
Eclipse
荧光光谱仪
Agilent
Eclipse
製造年份
2017
狀況
二手
位置
英国 

顯示圖片
显示地图
价格和位置
- 位置:
- Location:Duxford, United Kingdom
撥打
优惠详情
- 產品ID:
- A18143956
- 參考編號:
- 412977
- 最後更新:
- 於 25.02.2025
描述
Condition Used
Stock Number 412977
This listing is for a Agilent Eclipse Fluorescence Spectrometer.
Knedjvl A Ayjpfx Af Asc
The unit is in full working condition and is ready for immediate release.
Supplied with cables, software disk, License key,spare diffuser and Neutral density attenuator.
The Agilent Cary Eclipse fluorescence spectrometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
Type:Benchtop fluorescence spectrometer
Control Software :Cary WinFLR
Light Source:Xenon flash lamp (80 Hz) with 10-year warranty on new instruments
Maximum Scanning Speed :24,000 nm/min
Modes of Operation:Fluorescence,Phosphorescence,Chemiluminescence,Biolumi nescence,Time resolved phosphorescence.
Power Requirements:100-240 VAC, 50/60 Hz
Spectral Bandwidth Emission: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Excitation: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Wavelength Accuracy:± 1.5 nm
Wavelength Range:Operational emission: 200 - 900 nm
Operational excitation: 200 - 900 nm
Depth:644 mm
Height:271 mm
Weight:30 kg
Width:608 mm
Stock Number 412977
This listing is for a Agilent Eclipse Fluorescence Spectrometer.
Knedjvl A Ayjpfx Af Asc
The unit is in full working condition and is ready for immediate release.
Supplied with cables, software disk, License key,spare diffuser and Neutral density attenuator.
The Agilent Cary Eclipse fluorescence spectrometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
Type:Benchtop fluorescence spectrometer
Control Software :Cary WinFLR
Light Source:Xenon flash lamp (80 Hz) with 10-year warranty on new instruments
Maximum Scanning Speed :24,000 nm/min
Modes of Operation:Fluorescence,Phosphorescence,Chemiluminescence,Biolumi nescence,Time resolved phosphorescence.
Power Requirements:100-240 VAC, 50/60 Hz
Spectral Bandwidth Emission: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Excitation: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm 10 nm round nm
Wavelength Accuracy:± 1.5 nm
Wavelength Range:Operational emission: 200 - 900 nm
Operational excitation: 200 - 900 nm
Depth:644 mm
Height:271 mm
Weight:30 kg
Width:608 mm
您的广告已成功删除
发生错误