固定价格 不包含增值稅
€28,000
狀況
二手
位置
Borken 

顯示圖片
显示地图
机器数据
价格和位置
固定价格 不包含增值稅
€28,000
- 位置:
- Einsteinstraße 8a, 46325 Borken, DE
撥打
优惠详情
- 產品ID:
- A17902976
- 參考編號:
- 24455
- 最後更新:
- 於 04.12.2024
描述
HPLC Waters
The system consists of these modules and components:
Iiedpfsvcnpajx Af Aoh
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
The system consists of these modules and components:
Iiedpfsvcnpajx Af Aoh
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.