VACON Danfoss AC Drive NXI01405-A0T0CSS-A1AFA50000+FL23+DLDE 75kW 400V Common DC Bus Inverter Unit
Core Drive Specifications
NXI: NX Inverter Unit. Operates on a common DC bus system.
0140: 140 Amps Nominal Current Rating.Heavy Duty (High Overload): 105 A continuous output (75 kW / 100 HP motor rating).
Continuous/Low Overload: 140 A continuous output (90 kW / 125 HP motor rating).
5: Mains Voltage Class. Rated for 380 V to 500 V AC grid integration (465 V to 800 V DC bus input).
A: Includes the Standard Alpha-numeric Control Keypad.
Chodpfey Ud Arox Aahoa
0: IP00 Enclosure Class. This is an open-chassis module designed strictly for mounting inside a clean, protective industrial control cabinet.
T: Standard EMC Emission Level adhering to the IEC61800-3 specification for IT networks.
0: No integrated brake chopper unit.
C: Physical frame generation / module sizing designated as Frame FR8.
S: Standard Air-Cooled system.
S: Standard/Uncoated Circuit Boards (unlike your previous 'V' variant, this module relies on the external cabinet enclosure for environmental protection).
Internal Expansion Board Configuration (A1AFA50000)
The slot mapping outlines the factory-installed I/O and communication boards:
Slot A (A1): OPT-A1 Basic I/O Board. Standard logic board providing 6 digital inputs, 1 digital output, 2 analog inputs, and 1 analog output.
Slot B (AF): OPT-AF Dual Relay Output Board. Adds 2 programmable changeover relay outputs (NO/NC).
Slot C (A5): OPT-A5 Encoder Board. A specialized card providing an interface for a digital encoder/pulse generator (typically 5V or 15V), enabling precise closed-loop speed and torque motor control.
Slots D & E (0000): Remaining expansion slots are left empty for future modifications.
Factory Plus Codes (+FL23+DLDE)
These additions dictate specific firmware, testing, or documentation criteria:
+FL23: Specifies a customized factory application software loadout or programming setting tailored to a specific automation configuration.
+DLDE: German language and documentation pack (typically dictates the physical manuals, labeling, or software default language region).
Brand new never used. Please check out our other listings as well.
Core Drive Specifications
NXI: NX Inverter Unit. Operates on a common DC bus system.
0140: 140 Amps Nominal Current Rating.Heavy Duty (High Overload): 105 A continuous output (75 kW / 100 HP motor rating).
Continuous/Low Overload: 140 A continuous output (90 kW / 125 HP motor rating).
5: Mains Voltage Class. Rated for 380 V to 500 V AC grid integration (465 V to 800 V DC bus input).
A: Includes the Standard Alpha-numeric Control Keypad.
Chodpfey Ud Arox Aahoa
0: IP00 Enclosure Class. This is an open-chassis module designed strictly for mounting inside a clean, protective industrial control cabinet.
T: Standard EMC Emission Level adhering to the IEC61800-3 specification for IT networks.
0: No integrated brake chopper unit.
C: Physical frame generation / module sizing designated as Frame FR8.
S: Standard Air-Cooled system.
S: Standard/Uncoated Circuit Boards (unlike your previous 'V' variant, this module relies on the external cabinet enclosure for environmental protection).
Internal Expansion Board Configuration (A1AFA50000)
The slot mapping outlines the factory-installed I/O and communication boards:
Slot A (A1): OPT-A1 Basic I/O Board. Standard logic board providing 6 digital inputs, 1 digital output, 2 analog inputs, and 1 analog output.
Slot B (AF): OPT-AF Dual Relay Output Board. Adds 2 programmable changeover relay outputs (NO/NC).
Slot C (A5): OPT-A5 Encoder Board. A specialized card providing an interface for a digital encoder/pulse generator (typically 5V or 15V), enabling precise closed-loop speed and torque motor control.
Slots D & E (0000): Remaining expansion slots are left empty for future modifications.
Factory Plus Codes (+FL23+DLDE)
These additions dictate specific firmware, testing, or documentation criteria:
+FL23: Specifies a customized factory application software loadout or programming setting tailored to a specific automation configuration.
+DLDE: German language and documentation pack (typically dictates the physical manuals, labeling, or software default language region).
Brand new never used. Please check out our other listings as well.