Vötsch VT 7030 S2 温度冲击测试箱 300升 环境试验箱 TS05Vötsch
VT 7030 S2
Vötsch VT 7030 S2 温度冲击测试箱 300升 环境试验箱 TS05
Vötsch
VT 7030 S2
VB 不含增值税
€12,184
出厂年份
1998
状况
二手
位置
Borken 

基本数据
价格和位置
VB 不含增值税
€12,184
- 位置:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

拨打
优惠详情
- 广告编号:
- A18910781
- 参考编号:
- 46212
- 更新:
- 最近更新时间为 07.10.2026
描述
Vötsch VT 7030 S2 Temperature Shock Test Chamber
System for extreme temperature changes
During temperature shock testing, the resistance of components, devices, and other products to rapid changes in ambient temperature is tested.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
Based on these cyclical loads and accelerated aging caused by temperature changes, weaknesses in the test specimen can be identified.
Vertical arrangement of the test chambers
Ball screw drive for secure guidance of the moving carriage
Gsdpewbdv Sjfx Abqouh
All-round grids in the moving carriage secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
The warm chamber can be used as a temperature storage device, and the cold chamber can be used as a temperature cycling device
Touch panel for convenient operation of the simulation programs with graphical display
Minimal energy consumption
No compressed air required
Data for temperature tests in single-chamber operation
Warm chamber:
Temperature shock test chamber, test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation over time in the center of the usable space ± 1 K
Temperature deviation spatially ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in the supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber, test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation over time in the center of the usable space ± 1 K
Temperature deviation spatially 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in the supply air)
Heating 1.5 K/min
Cooling 4 K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10%, 50 Hz
Rated power: 30 kW
Rated current: 50 A
Refrigerant: R-404a / R-23
Refrigerating unit: Water-cooled
Weight: approx. 940 kg
Year of construction: 1998
Test chamber dimensions: Width 770 mm x Depth 650 mm x Height 610 mm
Housing dimensions: Width 1200 mm x Depth 1800 mm x Height 2050 mm
TS 05
You can find more items - new and used - in our shop! International shipping costs on request!
该广告为自动翻译,可能存在翻译错误。
System for extreme temperature changes
During temperature shock testing, the resistance of components, devices, and other products to rapid changes in ambient temperature is tested.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
Based on these cyclical loads and accelerated aging caused by temperature changes, weaknesses in the test specimen can be identified.
Vertical arrangement of the test chambers
Ball screw drive for secure guidance of the moving carriage
Gsdpewbdv Sjfx Abqouh
All-round grids in the moving carriage secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
The warm chamber can be used as a temperature storage device, and the cold chamber can be used as a temperature cycling device
Touch panel for convenient operation of the simulation programs with graphical display
Minimal energy consumption
No compressed air required
Data for temperature tests in single-chamber operation
Warm chamber:
Temperature shock test chamber, test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation over time in the center of the usable space ± 1 K
Temperature deviation spatially ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in the supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber, test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation over time in the center of the usable space ± 1 K
Temperature deviation spatially 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in the supply air)
Heating 1.5 K/min
Cooling 4 K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10%, 50 Hz
Rated power: 30 kW
Rated current: 50 A
Refrigerant: R-404a / R-23
Refrigerating unit: Water-cooled
Weight: approx. 940 kg
Year of construction: 1998
Test chamber dimensions: Width 770 mm x Depth 650 mm x Height 610 mm
Housing dimensions: Width 1200 mm x Depth 1800 mm x Height 2050 mm
TS 05
You can find more items - new and used - in our shop! International shipping costs on request!