专为电池测试优化的气候试验箱Vötsch
VCZ 60006/-1/S -60 bis +160
专为电池测试优化的气候试验箱
Vötsch
VCZ 60006/-1/S -60 bis +160
状况
二手
位置
Borken 

显示图片
显示地图
机器数据
价格和位置
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

拨打
优惠详情
- 广告编号:
- A21671963
- 参考编号:
- 25129
- 更新:
- 最近更新时间为 10.04.2026
描述
Vötsch
Gbsdpfx Aaeyzpa Nodjk
The unit was used for battery testing.
Inert gas connection and pressure compensation flap.
+Fresh air purge approx. 100 m³/h
Water-cooled
Model: VCZ 60006/-1/S
Large-capacity chamber for temperature and climate testing
Test chamber volume: approx. 7.5 m³
Interior dimensions: approx. height 1480 mm, width 2470 mm, depth 2050 mm
External dimensions: approx. height 2400 mm, width 3200 mm, depth 4270 mm
Test chamber floor load capacity: 3000 kg/m²
Temperature testing data:
Temperature range: -40°C to +160°C
Heating rate from -40 to +100°C: approx. 1 K/min
Cooling rate from +100 to -40°C: approx. 1.5 K/min
Heat compensation from -40°C to +20°C: 8000 W
Climate testing data:
Temperature range: +10 to +80°C
Humidity range: 10 to 90 % r.h.
Dew point range: +5 to +77.4°C
Temperature deviation over time: +/-0.1 to +/-0.5 K
Humidity deviation over time: +/-3 to +/-5% r.h.
Operational data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 25 kW
Nominal current: 41 A
Weight: 3500 kg
Refrigerants: R-404A / R-23 6.5 kg & 3.2 kg
For your safety as a buyer, please note the following information:
The following steps are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Leak test with certificate
3. After successful inspection, the chambers are subjected to a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see picture)
(Technical data and specifications subject to change and errors excepted!)
If you have any further questions, we would be happy to answer them by phone.
该广告为自动翻译,可能存在翻译错误。
Gbsdpfx Aaeyzpa Nodjk
The unit was used for battery testing.
Inert gas connection and pressure compensation flap.
+Fresh air purge approx. 100 m³/h
Water-cooled
Model: VCZ 60006/-1/S
Large-capacity chamber for temperature and climate testing
Test chamber volume: approx. 7.5 m³
Interior dimensions: approx. height 1480 mm, width 2470 mm, depth 2050 mm
External dimensions: approx. height 2400 mm, width 3200 mm, depth 4270 mm
Test chamber floor load capacity: 3000 kg/m²
Temperature testing data:
Temperature range: -40°C to +160°C
Heating rate from -40 to +100°C: approx. 1 K/min
Cooling rate from +100 to -40°C: approx. 1.5 K/min
Heat compensation from -40°C to +20°C: 8000 W
Climate testing data:
Temperature range: +10 to +80°C
Humidity range: 10 to 90 % r.h.
Dew point range: +5 to +77.4°C
Temperature deviation over time: +/-0.1 to +/-0.5 K
Humidity deviation over time: +/-3 to +/-5% r.h.
Operational data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 25 kW
Nominal current: 41 A
Weight: 3500 kg
Refrigerants: R-404A / R-23 6.5 kg & 3.2 kg
For your safety as a buyer, please note the following information:
The following steps are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Leak test with certificate
3. After successful inspection, the chambers are subjected to a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see picture)
(Technical data and specifications subject to change and errors excepted!)
If you have any further questions, we would be happy to answer them by phone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
您的广告已成功删除
发生错误