Vötsch
Type: VC 7018
Vötsch Climate Testing Chamber VC 7018, Water-Cooled
Hfsdpfxezh Huhs Aa Ton
Control Panel: “Touch Panel”
All control and operating commands can be initiated by simply touching the function symbols on the “Touch Panel” control panel.
Adjustable Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the testing chamber.
Feedthroughs installed as standard:
R1: 125 mm
L1: 50 mm
Testing chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Performance data for temperature tests:
Temperature range: -70°C to +180°C
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Performance data for climate tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% RH
Temporal temperature deviation in the center of the usable space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Temporal humidity deviation in the center of the usable space: ±1 to ±3 % RH
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse: 16 A, slow-blow, provided on site
Refrigerant: R-404A and R-23
Testing chamber volume: approx. 190 liters
Weight: approx. 460 kg net
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
该广告为自动翻译,可能存在翻译错误。
Type: VC 7018
Vötsch Climate Testing Chamber VC 7018, Water-Cooled
Hfsdpfxezh Huhs Aa Ton
Control Panel: “Touch Panel”
All control and operating commands can be initiated by simply touching the function symbols on the “Touch Panel” control panel.
Adjustable Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the testing chamber.
Feedthroughs installed as standard:
R1: 125 mm
L1: 50 mm
Testing chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Performance data for temperature tests:
Temperature range: -70°C to +180°C
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Performance data for climate tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% RH
Temporal temperature deviation in the center of the usable space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Temporal humidity deviation in the center of the usable space: ±1 to ±3 % RH
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse: 16 A, slow-blow, provided on site
Refrigerant: R-404A and R-23
Testing chamber volume: approx. 190 liters
Weight: approx. 460 kg net
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
这些广告您可能也感兴趣。
成功
您的消息已发送。
小广告
Borken
9,474 km
Vötsch 气候测试箱 VCS 7034-5,工作温度范围:-70°C 至 +180°C,容积 335 升,带湿度控制。
VötschKlimaprüfschrank
VötschKlimaprüfschrank
成功
您的消息已发送。
小广告
Borken
9,476 km
Vötsch VT 7012 S2 温度冲击试验箱 -70至220°C 冲击测试箱
VötschVT 7012 S2
VötschVT 7012 S2
成功
您的消息已发送。
小广告
Borken
9,474 km
Vötsch 气候测试箱 VCS 7034-5,工作温度范围:-70°C 至 +180°C,容积 335 升,带湿度控制。
Heraeus VötschVötsch Klimaprüfschrank
Heraeus VötschVötsch Klimaprüfschrank
成功
您的消息已发送。
小广告
Borken
9,474 km
Vötsch 气候测试箱 VCS 7034-5,工作温度范围:-70°C 至 +180°C,容积 335 升,带湿度控制。
Heraeus VötschVötsch Klimaprüfschrank
Heraeus VötschVötsch Klimaprüfschrank
成功
您的消息已发送。
小广告
Borken
9,474 km
Vötsch气候测试箱VCS 7033,温度范围-70°C至+180°C,带湿度调节功能。
Heraeus VötschVötsch Klimaprüfschrank
Heraeus VötschVötsch Klimaprüfschrank
成功
您的消息已发送。
小广告
Borken
9,474 km
-72至+180°C,480升,带湿度控制
Vötsch ClimeEventC/480/70/15 Klimaprüfschrank
Vötsch ClimeEventC/480/70/15 Klimaprüfschrank
您的广告已成功删除
发生错误