洁净室更衣室ULKEY
洁净室更衣室
ULKEY
製造年份
2017
狀況
二手
位置
Tamási 

顯示圖片
显示地图
价格和位置
- 位置:
- Tamási, 7090 Ungarn

撥打
优惠详情
- 產品ID:
- A21169237
- 參考編號:
- 8000001
- 最後更新:
- 於 05.02.2026
描述
Changing Room and Personal Entry Area:
Dimensions: 2000 x 2000 x 3000 mm
The changing room is divided into two zones: a gray zone and a white zone.
In the gray zone, personnel remove the footwear and gowns worn in the assembly area, sit on the bench separating the zones, and change into cleanroom footwear and gowns. Whenever personnel leave the cleanroom during operations, they must always change their attire upon re-entry.
Cleanroom:
Dimensions: 5500 x 4500 x 3000 mm
The goods-in zone is separated from the cleanroom adhesive area (1750 x 750 x 3000 mm).
Doors and windows between the goods-in zone and the cleanroom are interlocked; only one door or window can be opened at a time.
Upon entry: doors only open after a 6-minute delay, except when issuing storage devices, when no 6-minute lockout is applied.
After processing, the glued products are mechanically transferred to the assembly area via a pass-through window. Delivery windows must always be closed after the transfer process.
The cleanroom is pressurized, regulated via control dampers.
Air of ISO8 quality is supplied to the cleanroom through filters installed in the air handling unit.
Air handling units are installed on the support structure above the cleanroom ceiling.
Air cleanliness is continuously monitored and recorded.
If air cleanliness falls below acceptable levels, a visual alarm notifies personnel, or intervention in the production process occurs and doors and windows are locked.
Supply Fan:
Air volume: 8,000 m³/h
Static pressure: 400 Pa
400 V, 50 Hz, k kW
With silencer
Ventilation ductwork
HEPA filter
Frame Structure:
Powder-coated
Manufactured from cold-rolled profile materials
Side Walls, Roof Structure:
LV80 Kingspan sandwich panels
3 fixed windows, transparent and thermally insulated
2 entry doors, each with a fixed, transparent upper window
2 hatch doors, each with a fixed, transparent upper window
1 outlet opening with sliding window sash
Electrical Control:
Electrical distribution cabinet
Control cabinet
Frequency converter
Measuring instruments
Cgjdpoyhbczsfx Aggen
Monitoring System:
Vision monitoring system
Data storage computing unit (laptop)
Changing Room Furnishings:
Gray zone:
- Shoe storage
- Coat storage
- Hanging zone
- Dividing floor
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
Dimensions: 2000 x 2000 x 3000 mm
The changing room is divided into two zones: a gray zone and a white zone.
In the gray zone, personnel remove the footwear and gowns worn in the assembly area, sit on the bench separating the zones, and change into cleanroom footwear and gowns. Whenever personnel leave the cleanroom during operations, they must always change their attire upon re-entry.
Cleanroom:
Dimensions: 5500 x 4500 x 3000 mm
The goods-in zone is separated from the cleanroom adhesive area (1750 x 750 x 3000 mm).
Doors and windows between the goods-in zone and the cleanroom are interlocked; only one door or window can be opened at a time.
Upon entry: doors only open after a 6-minute delay, except when issuing storage devices, when no 6-minute lockout is applied.
After processing, the glued products are mechanically transferred to the assembly area via a pass-through window. Delivery windows must always be closed after the transfer process.
The cleanroom is pressurized, regulated via control dampers.
Air of ISO8 quality is supplied to the cleanroom through filters installed in the air handling unit.
Air handling units are installed on the support structure above the cleanroom ceiling.
Air cleanliness is continuously monitored and recorded.
If air cleanliness falls below acceptable levels, a visual alarm notifies personnel, or intervention in the production process occurs and doors and windows are locked.
Supply Fan:
Air volume: 8,000 m³/h
Static pressure: 400 Pa
400 V, 50 Hz, k kW
With silencer
Ventilation ductwork
HEPA filter
Frame Structure:
Powder-coated
Manufactured from cold-rolled profile materials
Side Walls, Roof Structure:
LV80 Kingspan sandwich panels
3 fixed windows, transparent and thermally insulated
2 entry doors, each with a fixed, transparent upper window
2 hatch doors, each with a fixed, transparent upper window
1 outlet opening with sliding window sash
Electrical Control:
Electrical distribution cabinet
Control cabinet
Frequency converter
Measuring instruments
Cgjdpoyhbczsfx Aggen
Monitoring System:
Vision monitoring system
Data storage computing unit (laptop)
Changing Room Furnishings:
Gray zone:
- Shoe storage
- Coat storage
- Hanging zone
- Dividing floor
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
您的广告已成功删除
发生错误









































