BDVA-HV 1000-10Ruhstrat
Transformator
BDVA-HV 1000-10
Ruhstrat
Transformator
起拍價 不包含增值稅
€20,000
製造年份
2025
狀況
全新
位置
Leuna 

顯示圖片
显示地图
机器数据
价格和位置
起拍價 不包含增值稅
€20,000
- 位置:
- Leuna, 德国
撥打
技术细节
- 输入电流类型:
- 空调
- 总重量:
- 2,750 千克
- 输入电压:
- 10,000 V
- 输入频率:
- 50 赫兹
- 总高度:
- 1,953 毫米
- 总宽度:
- 1,000 毫米
- 总长度:
- 1,600 毫米
- 保修期限:
- 72 个月
- 额定(视在)功率:
- 1,000 千伏安
- 额定功率:
- 1,000 千瓦 (1,359.62 马力)
- 次级电压:
- 400 V
- 防护类型(IP代码):
- IP00
- 温度:
- 40 °C
- 空载重量:
- 2,750 千克
- 所需宽度:
- 1,600 毫米
- 空间需求 长度:
- 1,000 毫米
- 所需高度:
- 1,920 毫米
- 环境温度(最大):
- 40 °C
- 行距:
- 820 毫米
- 设备:
- 文档 / 手册, 铭牌可用
优惠详情
- 產品ID:
- A18869326
- 參考編號:
- 700134
- 最後更新:
- 於 30.09.2025
描述
Three-phase cast-resin transformer
Designed according to DIN EN 60076-11, VDE 0532, with separate winding
Reduced no-load losses in accordance with Ecodesign Regulation EU No. 548/2014, Eco Directive 2009/125/EC
Design features:
- Flame-retardant and self-extinguishing
- High-voltage winding vacuum-encapsulated, low-voltage winding vacuum-impregnated
- Partial discharge-free (< 5 pC)
- Taps can be changed in the de-energized state using switch lugs
- Mobile design, 4 interchangeable transport rollers
- Winding material: aluminum/aluminum
- 4 lifting eyes, 4 draw eyes, 2 grounding screws
- Documentation: Dimensional drawing, nameplate, data sheet, circuit diagram, operating instructions in German/English - Use of double-sided insulated, grain-oriented, low-loss electrical steel sheets
- Reduced power losses A0 Level 2/Ak (Eco Directive 2009/125/EC)
- Suitable for converter operation, THDu < 5%
- 3x PT100 connected to terminals in the terminal box (IP 54)
RATED POWER: 1000 kVA
CIRCUIT: Dyn5
OVERVOLTAGE: 10 kV, with a value of ± 2x 2.5%
Gkodpfx Aov U Ncref Aec
FREQUENCY: 50 Hz
UNDERVOLTAGE: 400 V + N
SHORT-CIRCUIT VOLTAGE: 6% (tolerance ±10%)
NO-LOAD CURRENT: 0.6% (tolerance +30%)
INSULATION LEVEL HV (AC/LI): 12/28/75 kV – L2
INSULATION LEVEL LV (AC/LI):
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
Designed according to DIN EN 60076-11, VDE 0532, with separate winding
Reduced no-load losses in accordance with Ecodesign Regulation EU No. 548/2014, Eco Directive 2009/125/EC
Design features:
- Flame-retardant and self-extinguishing
- High-voltage winding vacuum-encapsulated, low-voltage winding vacuum-impregnated
- Partial discharge-free (< 5 pC)
- Taps can be changed in the de-energized state using switch lugs
- Mobile design, 4 interchangeable transport rollers
- Winding material: aluminum/aluminum
- 4 lifting eyes, 4 draw eyes, 2 grounding screws
- Documentation: Dimensional drawing, nameplate, data sheet, circuit diagram, operating instructions in German/English - Use of double-sided insulated, grain-oriented, low-loss electrical steel sheets
- Reduced power losses A0 Level 2/Ak (Eco Directive 2009/125/EC)
- Suitable for converter operation, THDu < 5%
- 3x PT100 connected to terminals in the terminal box (IP 54)
RATED POWER: 1000 kVA
CIRCUIT: Dyn5
OVERVOLTAGE: 10 kV, with a value of ± 2x 2.5%
Gkodpfx Aov U Ncref Aec
FREQUENCY: 50 Hz
UNDERVOLTAGE: 400 V + N
SHORT-CIRCUIT VOLTAGE: 6% (tolerance ±10%)
NO-LOAD CURRENT: 0.6% (tolerance +30%)
INSULATION LEVEL HV (AC/LI): 12/28/75 kV – L2
INSULATION LEVEL LV (AC/LI):