热冲击测试装置 –70至+240 °CRS-Simulatoren
ST2K320/70D
热冲击测试装置 –70至+240 °C
RS-Simulatoren
ST2K320/70D
狀況
二手
位置
Borken 

顯示圖片
显示地图
机器数据
价格和位置
- 位置:
- Einsteinstraße 8a, 46325 Borken, DE
撥打
优惠详情
- 產品ID:
- A19523991
- 參考編號:
- 24684
- 最後更新:
- 於 08.07.2025
描述
RS Simulators
RS Simulators ST2K 320/70D
Water-cooled Shock Test System
For sale is a high-performance thermal shock test system, model ST2K 320/70D.
This unit is ideally suited for standardized thermal shock testing
Laedpfx Ajwx Ip Def Ajh
according to DIN EN 60068‑2‑14, including optional humidity testing in the upper test chamber.
With its two temperature chambers (–70 °C to +240 °C) and automatic test basket transfer, this system provides the perfect solution for component, material, and reliability testing in industry, research, and quality assurance.
Main technical data:
Temperature ranges:
Upper test chamber: +40 °C to +240 °C
Temporal deviation: ±0.8 K (per DIN 50011, empty chamber)
Lower test chamber: –70 °C to +240 °C
Temporal deviation: ±0.8 K (per DIN 50011, empty chamber)
Optional humidity test – Upper test chamber:
Temperature: +40 °C to +90 °C
Relative humidity: 20% to 98% r.h. (±2–5%)
Test basket transfer:
Vertical movement, < 10 seconds changeover time
Power supply:
Total power: 16 kVA
Current consumption: 32 A
Main fuse: 3 × 35 A slow-blow
Mains connection: 3 × 400 V / N / PE / 50 Hz
Main cable: 5 × 16 mm²
Water & compressed air connections:
Cooling water inlet: G ¾", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 1.4 m³/h
Cooling water return: G ¾", max. 25.2 °C
Condensate drains: 2 × G ½", 1 × G ¼", unpressurized
Deionized water inlet: G ⅜", approx. 3 bar, max. 6 bar
Compressed air connection: Quick coupling NW 7.2 (G ¼"), min. 4 bar, max. 10 bar
Dimensions & weight:
Test basket internal dimensions (Type ST2K 320):
Internal dimensions: Width approx. 430 mm, Height approx. 470 mm, Depth approx. 700 mm
External dimensions: Width: approx. 1100 mm, Height: approx. 2300 mm, Depth: approx. 2300 mm
Weight: approx. 1150 kg
Other technical data:
Sound level: approx. 60 dB(A) at 1 m distance (free field)
Refrigerants:
R-404A: approx. 2.5 kg (GWP 3800, limit value 0.48 kg/m³)
R-23: approx. 0.8 kg (GWP 12100, limit value 0.68 kg/m³)
Permissible operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25%–75% r.h.
For your safety as the buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and details subject to change and errors reserved!)
We are happy to answer further questions by phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
RS Simulators ST2K 320/70D
Water-cooled Shock Test System
For sale is a high-performance thermal shock test system, model ST2K 320/70D.
This unit is ideally suited for standardized thermal shock testing
Laedpfx Ajwx Ip Def Ajh
according to DIN EN 60068‑2‑14, including optional humidity testing in the upper test chamber.
With its two temperature chambers (–70 °C to +240 °C) and automatic test basket transfer, this system provides the perfect solution for component, material, and reliability testing in industry, research, and quality assurance.
Main technical data:
Temperature ranges:
Upper test chamber: +40 °C to +240 °C
Temporal deviation: ±0.8 K (per DIN 50011, empty chamber)
Lower test chamber: –70 °C to +240 °C
Temporal deviation: ±0.8 K (per DIN 50011, empty chamber)
Optional humidity test – Upper test chamber:
Temperature: +40 °C to +90 °C
Relative humidity: 20% to 98% r.h. (±2–5%)
Test basket transfer:
Vertical movement, < 10 seconds changeover time
Power supply:
Total power: 16 kVA
Current consumption: 32 A
Main fuse: 3 × 35 A slow-blow
Mains connection: 3 × 400 V / N / PE / 50 Hz
Main cable: 5 × 16 mm²
Water & compressed air connections:
Cooling water inlet: G ¾", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 1.4 m³/h
Cooling water return: G ¾", max. 25.2 °C
Condensate drains: 2 × G ½", 1 × G ¼", unpressurized
Deionized water inlet: G ⅜", approx. 3 bar, max. 6 bar
Compressed air connection: Quick coupling NW 7.2 (G ¼"), min. 4 bar, max. 10 bar
Dimensions & weight:
Test basket internal dimensions (Type ST2K 320):
Internal dimensions: Width approx. 430 mm, Height approx. 470 mm, Depth approx. 700 mm
External dimensions: Width: approx. 1100 mm, Height: approx. 2300 mm, Depth: approx. 2300 mm
Weight: approx. 1150 kg
Other technical data:
Sound level: approx. 60 dB(A) at 1 m distance (free field)
Refrigerants:
R-404A: approx. 2.5 kg (GWP 3800, limit value 0.48 kg/m³)
R-23: approx. 0.8 kg (GWP 12100, limit value 0.68 kg/m³)
Permissible operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25%–75% r.h.
For your safety as the buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and details subject to change and errors reserved!)
We are happy to answer further questions by phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
您的广告已成功删除