差示扫描量热仪Perkin Elmer
DSC 8000, N5340524
差示扫描量热仪
Perkin Elmer
DSC 8000, N5340524
EXW 固定价格 不含增值税
€29,750
状况
二手
位置
Dresden 

显示图片
显示地图
机器数据
价格和位置
EXW 固定价格 不含增值税
€29,750
- 位置:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

拨打
优惠详情
- 广告编号:
- A21283042
- 参考编号:
- LW43630
- 更新:
- 最近更新时间为 20.02.2026
描述
Perkin Elmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells, UV/photocalorimeter accessories
Hfsdsyluicopfx Ag Ujf
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
该广告为自动翻译,可能存在翻译错误。
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells, UV/photocalorimeter accessories
Hfsdsyluicopfx Ag Ujf
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
该广告为自动翻译,可能存在翻译错误。
供應商
注意: 免费注册或登录,以获取所有信息。
注册于: 2014
97 在线广告
发送询价
电话 & 传真
+49 351 8... 广告
这些广告您可能也感兴趣。
小广告
Hannover
9,275 km
桌面金属工作室系统 II
Desktop MetalStudio System II
Desktop MetalStudio System II
小广告
Borken
9,474 km
10°C至+250°C / 749升
Memmert Universal - WärmeschrankUFP 800
Memmert Universal - WärmeschrankUFP 800
小广告
Borken
9,474 km
通用试验柜,温度范围:+20°C 至 +300°C
MemmertUF 450plus
MemmertUF 450plus
小广告
Wald
9,567 km
通用烘箱/加热炉/热风烘箱
MemmertULP 600
MemmertULP 600
小广告
西班牙
9,568 km
DESKTOP METAL Metal Studio 2
DESKTOP METALMetal Studio 2
DESKTOP METALMetal Studio 2
您的广告已成功删除
发生错误