加热与鼓风机Mobiler PCM Latentwärmespeicher
Wechselbrücke
加热与鼓风机
Mobiler PCM Latentwärmespeicher
Wechselbrücke
出厂年份
2022
状况
二手
(完全功能)
位置
Chemnitz 

机器数据
价格和位置
- 位置:
- Chemnitz, 德国

拨打
技术细节
- 功率:
- 1,300 千瓦 (1,767.51 马力)
- 总重量:
- 17,000 千克
- 温度:
- 25 °C
优惠详情
- 广告编号:
- A21276717
- 更新:
- 最近更新时间为 01.06.2026
描述
Description
A mobile PCM thermal storage unit
transports thermal energy (waste heat or process heat) using phase change materials (PCMs).
It stores heat through changes in its state of aggregation, achieving 2 to 4 times the capacity of conventional water tanks while maintaining compact dimensions. This system can be transported on a truck using a swap body system.
Storage capacity: 1.3 MWh of heat
Key operating principles & details
The principle (latent heat): Storage media such as paraffins or salt hydrates melt at specific temperatures, absorbing a large amount of heat in the process. When solidifying, this energy is released exactly at that temperature level.
Capacity & efficiency:
Since the energy (phase change) is stored without a noticeable temperature increase, the tanks have a significantly greater range. A modern mobile PCM storage unit typically holds storage volumes of several megawatt-hours (MWh).
Areas of application:
Perfect for supplying hospitals, schools, or swimming pools with district heating, or for residential complexes. The container can, for example, be fully charged at a biogas plant with excess heat and then transported to the point of use to release the heat.
Ideal for biogas plant operators or wood gas CHP plant operators, industry, etc., where process heat is available free of charge.
Technical data
Maximum
Storage temperature
75°C
Thermal storage capacity
gross 1300 kWh
Bodpeylmbqjfx Ap Aedc
Charging and discharging capacity max. 800 kW
Electronics on the storage unit: Data acquisition, monitoring, and transmission
Charging and discharging technology on the storage unit
Environmental compatibility: non-toxic, can be disposed of without harmful substances, recyclable
Connection: two supply and return lines, DN50, leak-proof, insulated, quick coupling
Grid connection: 400 kV
Logistics configurations: Standard container chassis, semi-trailer, swap body technology with twist locks,
trailer solution, adjustable thermal insulation hood
Dimensions: 6 x 2.55 m x 2.58 m (L/W/H) (~20 ft container)
Weight: 20 t
该广告为自动翻译,可能存在翻译错误。
A mobile PCM thermal storage unit
transports thermal energy (waste heat or process heat) using phase change materials (PCMs).
It stores heat through changes in its state of aggregation, achieving 2 to 4 times the capacity of conventional water tanks while maintaining compact dimensions. This system can be transported on a truck using a swap body system.
Storage capacity: 1.3 MWh of heat
Key operating principles & details
The principle (latent heat): Storage media such as paraffins or salt hydrates melt at specific temperatures, absorbing a large amount of heat in the process. When solidifying, this energy is released exactly at that temperature level.
Capacity & efficiency:
Since the energy (phase change) is stored without a noticeable temperature increase, the tanks have a significantly greater range. A modern mobile PCM storage unit typically holds storage volumes of several megawatt-hours (MWh).
Areas of application:
Perfect for supplying hospitals, schools, or swimming pools with district heating, or for residential complexes. The container can, for example, be fully charged at a biogas plant with excess heat and then transported to the point of use to release the heat.
Ideal for biogas plant operators or wood gas CHP plant operators, industry, etc., where process heat is available free of charge.
Technical data
Maximum
Storage temperature
75°C
Thermal storage capacity
gross 1300 kWh
Bodpeylmbqjfx Ap Aedc
Charging and discharging capacity max. 800 kW
Electronics on the storage unit: Data acquisition, monitoring, and transmission
Charging and discharging technology on the storage unit
Environmental compatibility: non-toxic, can be disposed of without harmful substances, recyclable
Connection: two supply and return lines, DN50, leak-proof, insulated, quick coupling
Grid connection: 400 kV
Logistics configurations: Standard container chassis, semi-trailer, swap body technology with twist locks,
trailer solution, adjustable thermal insulation hood
Dimensions: 6 x 2.55 m x 2.58 m (L/W/H) (~20 ft container)
Weight: 20 t
该广告为自动翻译,可能存在翻译错误。
供應商
注意: 免费注册或登录,以获取所有信息。
注册于: 2024
1 在线广告
发送询价
电话 & 传真
+49 176 3... 广告
这些广告您可能也感兴趣。
小广告
拉脱维亚
8,095 km
街区供热发电厂
SpannerBHKW45-8,0-V1.1
SpannerBHKW45-8,0-V1.1
小广告
德国
9,533 km
100 m³ 缓冲罐(钢制),隔热
小广告
Frankreich
10,111 km
模块化热电联产站
MTUCOGENERATIONENGINES AoE16V4000L62
MTUCOGENERATIONENGINES AoE16V4000L62
小广告
德国
9,303 km
热电联产厂
MAN/Daimler Benz/Krauter12 Zylinder/8 Zylinder
MAN/Daimler Benz/Krauter12 Zylinder/8 Zylinder
小广告
Newton Aycliffe
9,749 km
130千瓦,400伏,50赫兹 Man / Marelli 沼气热电联产机组
MANUPB 12-L-W-E3262E302
MANUPB 12-L-W-E3262E302
小广告
Brixen
9,475 km
热电联产厂
Spanner RE2 / Weissteiner Trockner
Spanner RE2 / Weissteiner Trockner
小广告
德国
9,174 km
发电机
Liebherr - AltronicG 924 TI
Liebherr - AltronicG 924 TI
小广告
德国
9,303 km
热电联产厂
KW Energiesmartblock 50
KW Energiesmartblock 50
小广告
Krotoszyn
8,847 km
缓冲干燥机,长度51米
小广告
Miastko
8,767 km
固定式提取系统
Nestro
Nestro
您的广告已成功删除