2004千瓦 Jenbacher JMS 612 GS-N.L 热电联产机组JENBACHER
JMS 612 GS-N.L.
2004千瓦 Jenbacher JMS 612 GS-N.L 热电联产机组
JENBACHER
JMS 612 GS-N.L.
狀況
二手
位置
葡萄牙 

顯示圖片
显示地图
机器数据
价格和位置
- 位置:
- Portugal
撥打
优惠详情
- 產品ID:
- A19886270
- 參考編號:
- RG1040
- 最後更新:
- 於 24.09.2025
描述
Used Jenbacher JMS 612 GS-N.L Gas-Powered CHP Plant
Manufactured in 2011, this combined heat and power (CHP) plant is currently configured for tri-generation — producing cooling, heating, and power within a single integrated process. Cooling is achieved via absorption chillers.
Technical Specifications:
Hodpfxsw T Rg To Af Aenu
Electrical output: 2,004 kWel
Thermal output: 4,551 kWt
Fuel consumption: 479 Nm³/h of natural gas
Gas flow rate: 2.79 kg/s
Exhaust gas temperature: 410 °C
Engine speed: 1,500 rpm
Inlet air temperature: Ambient +10 °C
Frequency: 50 Hz
Voltage: 6,300 V
Included Equipment:
Heat Recovery Boiler — Water tube design; gas flow 2.79 kg/s; inlet temperature 410 °C; outlet temperature 120 °C; water outlet 101 °C; water inlet 90 °C; recovery capacity 953 kWt.
Absorption Chiller — Refrigeration capacity 1,000 kWt; hot water flow 78.5 m³/h.
Plate Heat Exchanger — Constructed from 316 stainless steel; designed for producing hot process water using hot water recovered from the boiler.
Air Cooler — Ensures stable engine operation and optimized thermal efficiency.
Cooling Tower — Supports effective heat dissipation for continuous tri-generation performance.
More technical details, drawings, and operational data are available upon request.
Manufactured in 2011, this combined heat and power (CHP) plant is currently configured for tri-generation — producing cooling, heating, and power within a single integrated process. Cooling is achieved via absorption chillers.
Technical Specifications:
Hodpfxsw T Rg To Af Aenu
Electrical output: 2,004 kWel
Thermal output: 4,551 kWt
Fuel consumption: 479 Nm³/h of natural gas
Gas flow rate: 2.79 kg/s
Exhaust gas temperature: 410 °C
Engine speed: 1,500 rpm
Inlet air temperature: Ambient +10 °C
Frequency: 50 Hz
Voltage: 6,300 V
Included Equipment:
Heat Recovery Boiler — Water tube design; gas flow 2.79 kg/s; inlet temperature 410 °C; outlet temperature 120 °C; water outlet 101 °C; water inlet 90 °C; recovery capacity 953 kWt.
Absorption Chiller — Refrigeration capacity 1,000 kWt; hot water flow 78.5 m³/h.
Plate Heat Exchanger — Constructed from 316 stainless steel; designed for producing hot process water using hot water recovered from the boiler.
Air Cooler — Ensures stable engine operation and optimized thermal efficiency.
Cooling Tower — Supports effective heat dissipation for continuous tri-generation performance.
More technical details, drawings, and operational data are available upon request.