GBS Prüfpuls rev3 脉冲发生器,用于最高至 6nF 的长时间绝缘测试GBS Elektronik
rev3 Isolationstests bis 6nF
GBS Prüfpuls rev3 脉冲发生器,用于最高至 6nF 的长时间绝缘测试
GBS Elektronik
rev3 Isolationstests bis 6nF
VB 不含增值税
€3,781
状况
二手
位置
Borken 

基本数据
- 制造商:
- GBS Elektronik
- 状况:
- 二手
价格和位置
VB 不含增值税
€3,781
- 位置:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

拨打
优惠详情
- 广告编号:
- A17569468
- 参考编号:
- 21007
- 更新:
- 最近更新时间为 23.11.2026
描述
GBS Test Pulse rev3 Pulse Generator for Long-Term Insulation Tests up to 6 nF
The Test Pulse unit is designed for long-term insulation tests on test specimens with a capacitance of up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse Width Modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW.
· Pulse current limitation 110 A (shutdown threshold).
Pulse Transformer – Drive
· Drive via a full bridge.
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable.
· 2 selectable series inductances: 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacitance and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave.
· Cosine-shaped pulse at the transformer output.
Pulse Transformer Cascade
Lsdpfxou Egz Ro Acaorw
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz.
· Voltage divider 1:1000 in parallel.
· Overvoltage limitation at approximately 20-23 kV by parallel spark gaps.
· Thermistor for overtemperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown Detection, Testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approximately €59,500.
You can find more items – new and used – in our shop!
International shipping costs on request!
该广告为自动翻译,可能存在翻译错误。
The Test Pulse unit is designed for long-term insulation tests on test specimens with a capacitance of up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse Width Modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW.
· Pulse current limitation 110 A (shutdown threshold).
Pulse Transformer – Drive
· Drive via a full bridge.
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable.
· 2 selectable series inductances: 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacitance and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave.
· Cosine-shaped pulse at the transformer output.
Pulse Transformer Cascade
Lsdpfxou Egz Ro Acaorw
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz.
· Voltage divider 1:1000 in parallel.
· Overvoltage limitation at approximately 20-23 kV by parallel spark gaps.
· Thermistor for overtemperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown Detection, Testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.