锅炉Fiedler
SZDO-BS
锅炉
Fiedler
SZDO-BS
固定价格 不包含增值稅
€29,900
製造年份
2010
狀況
二手
位置
Cegléd 

顯示圖片
显示地图
价格和位置
固定价格 不包含增值稅
€29,900
- 位置:
- Kosarhegyi ut 22., 2700 Cegled, HU
撥打
优惠详情
- 產品ID:
- A16320817
- 最後更新:
- 於 19.06.2024
描述
Fiedler boiler for dryer - heat transfer medium flue gas
Dcedpfx Aaotwclvj Njn
We offer for sale our "Fiedler SZDO-BS" boiler.
Power: 1000 kW
Maximum temperature: 400 °C
Maximum flow rate: 2 m³/sec
Noise level: 78 dB
Total weight: 7500 kg
Power consumption: 2,7 kW
Electrical requirements: 3x400V/230, 50Hz
Production number: 356
Year of manufacture: 2010
The boiler is in excellent condition as shown in the pictures. The boiler body is insulated with samott bricks. The boiler has been sold due to the closure of the manufacturing plant.
Not in use but cold tests have been carried out.
No possibility to test it in operation.
The boiler is in automatic operation. The fuel is fed into the firebox by a pulley. The firebox is of the shrouded type, with inclined grate (but not moving), using primary and secondary air. The flue gas is mixed with fresh air in the 'afterburner' section of the boiler. The fresh air enters on the left side of the boiler. Its flow rate - and thus the drying air temperature - is controlled by an electrically operated butterfly valve.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
Dcedpfx Aaotwclvj Njn
We offer for sale our "Fiedler SZDO-BS" boiler.
Power: 1000 kW
Maximum temperature: 400 °C
Maximum flow rate: 2 m³/sec
Noise level: 78 dB
Total weight: 7500 kg
Power consumption: 2,7 kW
Electrical requirements: 3x400V/230, 50Hz
Production number: 356
Year of manufacture: 2010
The boiler is in excellent condition as shown in the pictures. The boiler body is insulated with samott bricks. The boiler has been sold due to the closure of the manufacturing plant.
Not in use but cold tests have been carried out.
No possibility to test it in operation.
The boiler is in automatic operation. The fuel is fed into the firebox by a pulley. The firebox is of the shrouded type, with inclined grate (but not moving), using primary and secondary air. The flue gas is mixed with fresh air in the 'afterburner' section of the boiler. The fresh air enters on the left side of the boiler. Its flow rate - and thus the drying air temperature - is controlled by an electrically operated butterfly valve.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
您的广告已成功删除
发生错误