描述
CTS
Temperature testing chamber T-55/1000 Li, water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Rated current: 18 A
Compressor: TFH2511Z / TFH2511Z, refrigerant R404A/R23
The type designation of the CTS chamber series is as follows:
e.g., Type T -55/1000/Li
1) T means: Temperature
2) -55 means: lower temperature -55°C
3) 1000 means: 1000-liter test chamber volume
4) Li means: special equipment for
testing with lithium-ion batteries
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for customer-specific
control of the test item
Test chamber lighting:
energy-efficient, bright LED light strip mounted on the door
Insert rack:
Stainless steel, support surface 970 x 980 mm
Load per rack max. 35 kg
Total load with max. rack load 100 kg
1a Conduit NW50
1b Conduit 2x NW125
1c Conduit 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Thermal compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25°C,
rated voltage 400V, without test item, without thermal compensation and without additional equipment.
Options can affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, Width, approx. 860 mm, Depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, Width, approx. 1270 mm, Depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(measured according to DIN EN ISO 3744
at a distance of 1 m from the front)
Weight approx. 1000 kg
Heat dissipation to the installation room 10.4 kW
Refrigeration unit:
water-cooled, low-noise, fully hermetic
stepless power adjustment by electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
Ncedpfxszg Ty Us Appsu
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have on the phone.
该广告为自动翻译,可能存在翻译错误。
Temperature testing chamber T-55/1000 Li, water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Rated current: 18 A
Compressor: TFH2511Z / TFH2511Z, refrigerant R404A/R23
The type designation of the CTS chamber series is as follows:
e.g., Type T -55/1000/Li
1) T means: Temperature
2) -55 means: lower temperature -55°C
3) 1000 means: 1000-liter test chamber volume
4) Li means: special equipment for
testing with lithium-ion batteries
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for customer-specific
control of the test item
Test chamber lighting:
energy-efficient, bright LED light strip mounted on the door
Insert rack:
Stainless steel, support surface 970 x 980 mm
Load per rack max. 35 kg
Total load with max. rack load 100 kg
1a Conduit NW50
1b Conduit 2x NW125
1c Conduit 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Thermal compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25°C,
rated voltage 400V, without test item, without thermal compensation and without additional equipment.
Options can affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, Width, approx. 860 mm, Depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, Width, approx. 1270 mm, Depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(measured according to DIN EN ISO 3744
at a distance of 1 m from the front)
Weight approx. 1000 kg
Heat dissipation to the installation room 10.4 kW
Refrigeration unit:
water-cooled, low-noise, fully hermetic
stepless power adjustment by electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
Ncedpfxszg Ty Us Appsu
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have on the phone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
您的广告已成功删除
发生错误