温度测试箱CTS
T -70/600
温度测试箱
CTS
T -70/600
状况
二手
位置
Borken 

显示图片
显示地图
价格和位置
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

拨打
优惠详情
- 广告编号:
- A21152132
- 参考编号:
- 23070
- 更新:
- 最近更新时间为 03.02.2026
描述
CTS Temperature Test Chamber
We are offering you a CTS temperature test chamber.
Water-cooled
CTS Temperature Test Chamber
Technical specifications:
Temperature operating range:
Temperature range: -70°C to +180°C
Cooling rate: 3.0 K/min
Heating rate: 3.5 K/min
Temperature stability, temporal: ≤± 0.3 K
Dimensions:
Test volume: 600 liters
Test chamber internal dimensions: Height approx. 850 mm, Width approx. 850 mm, Depth approx. 830 mm
External dimensions: Height approx. 1900 mm, Width approx. 1120 mm, Depth approx. 1875 mm
Operating data:
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Connected load: 8.2 kW, 14.2 A
Lodoygupfspfx Abdori
Refrigerant: R404A / R23
Weight: 600 kg
Model: T-70/600
Important Information for Buyers!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run monitored with calibrated equipment.
Condition: used
Scope of delivery: (see picture)
(Technical data, specifications, and information are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
该广告为自动翻译,可能存在翻译错误。
We are offering you a CTS temperature test chamber.
Water-cooled
CTS Temperature Test Chamber
Technical specifications:
Temperature operating range:
Temperature range: -70°C to +180°C
Cooling rate: 3.0 K/min
Heating rate: 3.5 K/min
Temperature stability, temporal: ≤± 0.3 K
Dimensions:
Test volume: 600 liters
Test chamber internal dimensions: Height approx. 850 mm, Width approx. 850 mm, Depth approx. 830 mm
External dimensions: Height approx. 1900 mm, Width approx. 1120 mm, Depth approx. 1875 mm
Operating data:
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Connected load: 8.2 kW, 14.2 A
Lodoygupfspfx Abdori
Refrigerant: R404A / R23
Weight: 600 kg
Model: T-70/600
Important Information for Buyers!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run monitored with calibrated equipment.
Condition: used
Scope of delivery: (see picture)
(Technical data, specifications, and information are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
这些广告您可能也感兴趣。
小广告
Borken
9,474 km
600 升温度试验箱
CTST-70/600 -70°C bis 180°C
CTST-70/600 -70°C bis 180°C
小广告
Borken
9,474 km
600 升温度试验箱
CTST-70/600/S -70°C bis 180°C
CTST-70/600/S -70°C bis 180°C
小广告
Borken
9,474 km
600 升温度试验箱
CTST-70/600/S 70°C bis 180°C
CTST-70/600/S 70°C bis 180°C
您的广告已成功删除