质量流量控制器 (MFC)Bronkhorst
F-201CI-10K-AGD-44-V
质量流量控制器 (MFC)
Bronkhorst
F-201CI-10K-AGD-44-V
EXW 固定价格 不含增值税
€600
状况
全新
(完全功能)
位置
Töltéstava 

基本数据
价格和位置
EXW 固定价格 不含增值税
€600
- 位置:
- 0184/3. Hrsz, 9086 Töltéstava, Hungary

拨打
优惠详情
- 广告编号:
- A22853505
- 更新:
- 最近更新时间为 30.09.2026
描述
!!! We have two pcs in stock. Price is for one pc only !!!
Performance & Measurement
• Measurement Principle: Thermal mass flow bypass sensor with a laminar flow element.
• Flow Range (10K Sub-code): Configured for low to mid-range capacities, nominal 0.08 to 10 ln/min (up to 15 ln/min max depending on the specific gas calibration).
• Accuracy: ±0.5% of Reading plus ±0.1% of Full Scale (standard for dry/clean gases).
• Repeatability: < ±0.2% of Reading.
• Settling Time: Standard 1 to 2 seconds.
• Turndown Ratio: 1:50 in analog mode (digitally extendable up to 1:187.5).
Mechanical & Environmental
Bdedpoz Hq Rbjfx Akwjh
• Ingress Protection: IP65 dust-tight and water-jet proof rugged housing.
• Pressure Rating: Up to 64 bar abs (PN64).
• Operating Temperature: -10°C to +70°C.
• Wetted Materials: Stainless steel 316L or equivalent.
• Weight: 1.4 kg.
Electrical & Communication
• Power Supply: +15…24 Vdc (±10%).
• Power Consumption: Max 320 mA (approx. 3.5 W typical at 24V).
• Analog I/O: 0…5 (10) Vdc or 0 (4)…20 mA.
• Digital Interfaces: Standard RS232 with configurable fieldbus options (e.g., PROFIBUS DP, DeviceNet, Modbus RTU, EtherCAT, PROFINET).
Model code breakdown:
• AGD: Represents the precise hardware configuration configuration, internal control valve size, and basic orifice profile.
• 44: Specifies the primary electrical connection setup (typically an 8-pin DIN male connector for power/analog/RS232 plus secondary M12 fieldbus options optimized for IP65 environments).
• V: Denotes Viton (FKM) internal elastomer seals and plunger materials.
Brand new never used. Please check out our other listings as well.
Performance & Measurement
• Measurement Principle: Thermal mass flow bypass sensor with a laminar flow element.
• Flow Range (10K Sub-code): Configured for low to mid-range capacities, nominal 0.08 to 10 ln/min (up to 15 ln/min max depending on the specific gas calibration).
• Accuracy: ±0.5% of Reading plus ±0.1% of Full Scale (standard for dry/clean gases).
• Repeatability: < ±0.2% of Reading.
• Settling Time: Standard 1 to 2 seconds.
• Turndown Ratio: 1:50 in analog mode (digitally extendable up to 1:187.5).
Mechanical & Environmental
Bdedpoz Hq Rbjfx Akwjh
• Ingress Protection: IP65 dust-tight and water-jet proof rugged housing.
• Pressure Rating: Up to 64 bar abs (PN64).
• Operating Temperature: -10°C to +70°C.
• Wetted Materials: Stainless steel 316L or equivalent.
• Weight: 1.4 kg.
Electrical & Communication
• Power Supply: +15…24 Vdc (±10%).
• Power Consumption: Max 320 mA (approx. 3.5 W typical at 24V).
• Analog I/O: 0…5 (10) Vdc or 0 (4)…20 mA.
• Digital Interfaces: Standard RS232 with configurable fieldbus options (e.g., PROFIBUS DP, DeviceNet, Modbus RTU, EtherCAT, PROFINET).
Model code breakdown:
• AGD: Represents the precise hardware configuration configuration, internal control valve size, and basic orifice profile.
• 44: Specifies the primary electrical connection setup (typically an 8-pin DIN male connector for power/analog/RS232 plus secondary M12 fieldbus options optimized for IP65 environments).
• V: Denotes Viton (FKM) internal elastomer seals and plunger materials.
Brand new never used. Please check out our other listings as well.
供應商
注意: 免费注册或登录,以获取所有信息。
注册于: 2020
267 在线广告
发送询价
电话 & 传真
+36 62 99... 广告
您的广告已成功删除
发生错误