Brinox 洗涤液恒温控制滑移装置BRINOX
LEP 13.1
Brinox 洗涤液恒温控制滑移装置
BRINOX
LEP 13.1
製造年份
2020
狀況
全新
位置
Solingen 

顯示圖片
显示地图
机器数据
价格和位置
- 位置:
- Landwehrstraße 55-65, 42699 Solingen, Deutschland

撥打
技术细节
- 设备:
- 文档 / 手册
优惠详情
- 產品ID:
- A21293747
- 參考編號:
- Paket 10 KK6770
- 最後更新:
- 於 21.02.2026
描述
Manufacturer: BRINOX
Product: LEP13.1 – AS-Batch Temperature Control Unit
System type: Temperature control unit for ammonium sulfate batch system
Year of manufacture: 2020
Serial number: 1003620
Tag number: MR-ASF-ASF61-KK6770
Equipment number: 20022748
Media Connections / Process Data
WCOV – Chilled water supply: 6 °C
WCOR – Chilled water return: 12 °C
WSV – Process/municipal water
AIP10 – Control compressed air 6 bar
Design as a closed temperature control module with integrated pump and heat exchanger technology.
Dimensions
Kdedpeyl Izxefx Abwoh
Overall dimensions as per layout:
approx. 1920 x 1435 x 1573 mm (L x W x H)
Compact, skid-mounted unit with welded stainless steel frame.
Construction
Frame construction in stainless steel
Fully insulated piping (industrial insulation)
Stainless steel shell-and-tube heat exchanger
Electrical inline water heater WT1011
Pump PU1021
Pump PU9203
Heat exchanger WT1001
Expansion vessel BH9701
Fittings:
GEMÜ shut-off valves
Pneumatically actuated valves
Manual ball valves
Pressure gauges
Sensors and instrumentation as per P&ID
Complete piping and component labeling provided.
Condition
New and in original packaging.
Not yet put into operation in production.
Factory new condition.
Supplied directly by the manufacturer Brinox.
FAT / Test Status
FAT carried out.
Leak test:
Test medium: Compressed air
Test pressure: approx. 3 bar
Holding time: 1 hour
Result: Passed
Calibration:
Pressure gauge calibrated
Measuring range: 0–10 bar
Calibration certificate available
Traceable to national standards
Documentation
Turn-Over-Package complete
Included documents:
FAT plan
FAT report
Non-conformance form
Layout drawing check
Maintenance and calibration accessibility check
P&ID review
Leak test report
Calibration certificates
Documentation check
Factory certificate 2.1 according to EN 10204
LBM material list incl. EU declarations
List of installed components – equipment
List of installed components – instrumentation points (PLT)
Material parts list for as-built isometry
Key Features
GMP-compliant construction
Pharma/biotech project quality
Full traceability
Compact plug-and-play skid design
Completely piped, insulated, and ready to connect
Immediately available
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
Product: LEP13.1 – AS-Batch Temperature Control Unit
System type: Temperature control unit for ammonium sulfate batch system
Year of manufacture: 2020
Serial number: 1003620
Tag number: MR-ASF-ASF61-KK6770
Equipment number: 20022748
Media Connections / Process Data
WCOV – Chilled water supply: 6 °C
WCOR – Chilled water return: 12 °C
WSV – Process/municipal water
AIP10 – Control compressed air 6 bar
Design as a closed temperature control module with integrated pump and heat exchanger technology.
Dimensions
Kdedpeyl Izxefx Abwoh
Overall dimensions as per layout:
approx. 1920 x 1435 x 1573 mm (L x W x H)
Compact, skid-mounted unit with welded stainless steel frame.
Construction
Frame construction in stainless steel
Fully insulated piping (industrial insulation)
Stainless steel shell-and-tube heat exchanger
Electrical inline water heater WT1011
Pump PU1021
Pump PU9203
Heat exchanger WT1001
Expansion vessel BH9701
Fittings:
GEMÜ shut-off valves
Pneumatically actuated valves
Manual ball valves
Pressure gauges
Sensors and instrumentation as per P&ID
Complete piping and component labeling provided.
Condition
New and in original packaging.
Not yet put into operation in production.
Factory new condition.
Supplied directly by the manufacturer Brinox.
FAT / Test Status
FAT carried out.
Leak test:
Test medium: Compressed air
Test pressure: approx. 3 bar
Holding time: 1 hour
Result: Passed
Calibration:
Pressure gauge calibrated
Measuring range: 0–10 bar
Calibration certificate available
Traceable to national standards
Documentation
Turn-Over-Package complete
Included documents:
FAT plan
FAT report
Non-conformance form
Layout drawing check
Maintenance and calibration accessibility check
P&ID review
Leak test report
Calibration certificates
Documentation check
Factory certificate 2.1 according to EN 10204
LBM material list incl. EU declarations
List of installed components – equipment
List of installed components – instrumentation points (PLT)
Material parts list for as-built isometry
Key Features
GMP-compliant construction
Pharma/biotech project quality
Full traceability
Compact plug-and-play skid design
Completely piped, insulated, and ready to connect
Immediately available
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
您的广告已成功删除
发生错误