带湿度控制的交变气候箱Binder
MKF 115 E3.1 -40°C bis 180°C
带湿度控制的交变气候箱
Binder
MKF 115 E3.1 -40°C bis 180°C
狀況
二手
位置
Borken 

顯示圖片
显示地图
机器数据
价格和位置
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

撥打
优惠详情
- 產品ID:
- A20959057
- 參考編號:
- 24976
- 最後更新:
- 於 15.01.2026
描述
Binder
Model MKF 115 E3.1
Binder Climatic Test Chamber Model MKF 115 E3.1
Temperature range: -40 °C to +180 °C
Humidity range: 10 % RH to 98 % RH
Integrated 20 L water reservoir
4 potential-free relay contacts
APT.line™ preheating chamber technology
Programmable condensation protection for samples
Heated viewing window with LED chamber illumination
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ Basic Edition
Fault diagnosis system with visual and audible alarms
Intuitive touchscreen controller with time-segment and real-time programming
Internal data logger, measurement data exportable in open format via USB
50 mm access port with silicone stopper, left side
Class 2 temperature safety limiter (DIN 12880) with visual alarm
4 casters (2 with locking brakes)
Computer interface: Ethernet
230 V outlet on right side control panel
Adjustable ramp function
Integrated strip chart recorder
Real-time clock
Door heating
Alarm notification on low water level in the fresh water tank
2 stainless steel shelves
Hose burst protection, incl. water supply and drain up to 1m height
Gtjdpox Ux Ivjfx Acvot
Interior chamber made of stainless steel
Cooling by compression refrigeration unit
TECHNICAL DATA:
Cabinet dimensions:
Width 1000 mm Height 1725 mm incl. feet/castors Depth 865 mm incl. lugs &/connections
Interior dimensions:
Width 600 mm Height 480 mm Depth 400 mm
Volume:
Chamber volume 115 liters
Net device weight (empty) 280 kg
Max. total load 60 kg
Max. load per shelf 30 kg
Performance data Temperature:
Temperature range -40...180°C
Temporal temperature deviation 0.1...0.6 ± K
Spatial temperature deviation 0.1...1.3 ± K
Average heat-up rate according to IEC 60068-3-5: 5.5 K/min
Average cool-down rate according to IEC 60068-3-5: 4.5 K/min
Max. heat compensation 2500 W
Climate performance data:
Temperature range 10...95°C
Humidity range 10...98 % RH
Temporal temperature deviation depending on setpoint 0.1...1.3 ± K
Max. heat compensation 400 W
Electrical data:
Rated voltage 400V 3N~ ±10% 50Hz
Rated power 4.5 kW 7.5 A
Energy consumption at 25°C / 60% RH 1.25 kW
Fittings:
Number of shelves 4/4 (std./max.)
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors!)
If you have further questions, we would be happy to answer them by phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
Model MKF 115 E3.1
Binder Climatic Test Chamber Model MKF 115 E3.1
Temperature range: -40 °C to +180 °C
Humidity range: 10 % RH to 98 % RH
Integrated 20 L water reservoir
4 potential-free relay contacts
APT.line™ preheating chamber technology
Programmable condensation protection for samples
Heated viewing window with LED chamber illumination
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ Basic Edition
Fault diagnosis system with visual and audible alarms
Intuitive touchscreen controller with time-segment and real-time programming
Internal data logger, measurement data exportable in open format via USB
50 mm access port with silicone stopper, left side
Class 2 temperature safety limiter (DIN 12880) with visual alarm
4 casters (2 with locking brakes)
Computer interface: Ethernet
230 V outlet on right side control panel
Adjustable ramp function
Integrated strip chart recorder
Real-time clock
Door heating
Alarm notification on low water level in the fresh water tank
2 stainless steel shelves
Hose burst protection, incl. water supply and drain up to 1m height
Gtjdpox Ux Ivjfx Acvot
Interior chamber made of stainless steel
Cooling by compression refrigeration unit
TECHNICAL DATA:
Cabinet dimensions:
Width 1000 mm Height 1725 mm incl. feet/castors Depth 865 mm incl. lugs &/connections
Interior dimensions:
Width 600 mm Height 480 mm Depth 400 mm
Volume:
Chamber volume 115 liters
Net device weight (empty) 280 kg
Max. total load 60 kg
Max. load per shelf 30 kg
Performance data Temperature:
Temperature range -40...180°C
Temporal temperature deviation 0.1...0.6 ± K
Spatial temperature deviation 0.1...1.3 ± K
Average heat-up rate according to IEC 60068-3-5: 5.5 K/min
Average cool-down rate according to IEC 60068-3-5: 4.5 K/min
Max. heat compensation 2500 W
Climate performance data:
Temperature range 10...95°C
Humidity range 10...98 % RH
Temporal temperature deviation depending on setpoint 0.1...1.3 ± K
Max. heat compensation 400 W
Electrical data:
Rated voltage 400V 3N~ ±10% 50Hz
Rated power 4.5 kW 7.5 A
Energy consumption at 25°C / 60% RH 1.25 kW
Fittings:
Number of shelves 4/4 (std./max.)
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors!)
If you have further questions, we would be happy to answer them by phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
您的广告已成功删除
发生错误