BD Phoenix M50自动化鉴定及药敏测试仪BD
Phoenix M50
BD Phoenix M50自动化鉴定及药敏测试仪
BD
Phoenix M50
固定价格 不包含增值稅
€15,930
狀況
二手
位置
Walton-on-the-Naze 

顯示圖片
显示地图
机器数据
价格和位置
固定价格 不包含增值稅
€15,930
- 位置:
- Walton-on-the-Naze, UK

撥打
优惠详情
- 產品ID:
- A20616795
- 參考編號:
- 5327356
- 最後更新:
- 於 26.11.2025
描述
This listing is for a two stacked BD Phoenix M50 Automated Identification & Susceptibility Testing Instrument
The BD Phoenix™ M50 instrument provides accurate and timely identification and susceptibility results to guide appropriate therapy and patient management decisions. The system can hold up to 50 panels at a time and can be stacked to maximize limited laboratory space. AST Panels have up to 29 antibiotics on a single panel to reduce offline testing and provide a true MIC value based on current CLSI breakpoint standards. It has demonstrated performance in detecting emerging resistance. It incorporates the use of an oxidation reduction indicator, turbidometric growth detection, full on-panel antimicrobial concentrations and the BDXpert™ System. Together these make up the Phoenix Susceptibility System resulting in rapid, accurate and reliable antimicrobial susceptibility results. These results are further enhanced by specific delayed resistance features, providing additional assurance that Phoenix results are not only rapid but accurate. The inclusion of all reported antimicrobial concentrations on the panel provides the foundation for detection of emerging resistance.
Two Stacked BD Phoenix M50 Instruments with PC specifiations:
Height: 42 in (107 cm)
Width: 53.5 in (136 cm)
Depth: 30 in (76.5 cm)
Clearance (left): 3 in (7.62 cm)
Psdoxzgw Nspfx Afrord
Clearance (right): 18 in (45.72 cm)
Weight: 240 lb (109 kg)
Power requirements: 90-264 VAC; 47-63 Hz 15 amp circuit
The BD Phoenix™ M50 instrument provides accurate and timely identification and susceptibility results to guide appropriate therapy and patient management decisions. The system can hold up to 50 panels at a time and can be stacked to maximize limited laboratory space. AST Panels have up to 29 antibiotics on a single panel to reduce offline testing and provide a true MIC value based on current CLSI breakpoint standards. It has demonstrated performance in detecting emerging resistance. It incorporates the use of an oxidation reduction indicator, turbidometric growth detection, full on-panel antimicrobial concentrations and the BDXpert™ System. Together these make up the Phoenix Susceptibility System resulting in rapid, accurate and reliable antimicrobial susceptibility results. These results are further enhanced by specific delayed resistance features, providing additional assurance that Phoenix results are not only rapid but accurate. The inclusion of all reported antimicrobial concentrations on the panel provides the foundation for detection of emerging resistance.
Two Stacked BD Phoenix M50 Instruments with PC specifiations:
Height: 42 in (107 cm)
Width: 53.5 in (136 cm)
Depth: 30 in (76.5 cm)
Clearance (left): 3 in (7.62 cm)
Psdoxzgw Nspfx Afrord
Clearance (right): 18 in (45.72 cm)
Weight: 240 lb (109 kg)
Power requirements: 90-264 VAC; 47-63 Hz 15 amp circuit
您的广告已成功删除